sebakmt UK - Innovative ideas for location, inspection and fault finding
Sunday, September 17, 2006
Teletech

TX120 SERIES DIGITAL LINE TEST SET

  1. Exchange Connect and Disconnect.
  2. Pair Identification.
  3. Noise measurement continuous and peak capture.
  4. Loop Resistance measurement.
  5. Line Isolation ( used for testing with other instruments ).
  6. Line Balance measurement.
  7. Insulation Resistance measurement ( A-B, A-GND, B-GND )
  8. Line Insertion Loss measurement @ 820Hz, 3kHz, 40kHz, 100kHz, 150kHz, 300kHz.
  9. Line Looping (used for PET distance calibration and for Varley Bridge Fault Location)
  10. Foreign Battery measurement (A-B,A-GND,B-GND) and Line Voltage measurement.

The new improved Digital Line Test Set is now available for immediate delivery. The TX120 Series is both a time and money saver, which combines the functions of several instruments into one comprehensive piece of equipment.

  • The TX120 Series includes all the functions of the upgraded Loop-a-Line used for Pair ID, remote line looping, exchange, connect/disconnect plus external terminals for line access to fault finding test instruments eg. PET, CZ3000.
  • Since its introduction to Telstra in 1997, the TX120 Series has found world wide acceptance, with well over 1,000 units supplied.
THE TX120 SERIES CONSISTS OF:

TX120 SERIES RECEIVER

  • Supplied with clip test lead.
  • Siemens Series 71 test lead.
  • Siemens Series 2000 test lead
  • Siemens Series 5000 test lead
  • Exchange power lead
  • Power by either exchange battery or 9V Alkaline battery. 
TX120 SERIES SENDER
  • Supplied with clip test lead
  • Krone test lead
  • Powered by 9V Alkaline battery

TX120 SERIES PROBE

  • For pair identification
  • Powered by 9V battery, 216 or Equivalent.
TECHNICAL SPECIFICATIONS
820Hz Loss
  • Range / Resolution
  • Sender Level
  • Impedance

0 to 20dBm / 0.1dBm
-10dBm
600Ohm and TN12

3kHz Loss

  • Range / Resolution
  • Sender Level
  • Impedance

0 to 20dBm / 0.1dBm
-10dBm
600Ohm and TN12

40kHz Loss
  • Range / Resolution
  • Sender Level
  • Impedance

0 to 60dBm / 1dBm
0dBm
(120 -j59) Ohm

100kHz Loss
  • Range / Resolution
  • Sender Level
  • Impedance

0 to 60dBm / 1dBm
0dBm
(120 -j23) Ohm

150kHz Loss
  • Range / Resolution
  • Sender Level
  • Impedance

0 to 60dBm / 1dBm
0dBm
(120 -j16) Ohm

300Hz Loss

  • Range / Resolution
  • Sender Level
  • Impedance

0 to 60dBm / 1dBm
0dBm
(120 -j8) Ohm

Noise
  • Range / Resolution
  • Weighting
  • Detection
  • Displays
  • Duration

-70 to -20dBm / 1dBm
3kHz Flat
Quasi-Peak
Continuous & Maximum
40 hrs (battery life)

Insulation Resistance
  • Tests
  • Range / Resolution
  • Source
  • Duration

A-B,A-GND,B-GND
0 to 200MOhm / 1MOhm
500 VDC
20 sec x 3

Loop Resistance
  • Range / Resolution
  • Source

0 to 3kOhm / 1Ohm
2.5 VDC

Line Balance
  • Range / Resolution
  • Source

40 to 70dB / 1dB
1Vrms, 3kHz

Foreign Battery
  • Tests
  • Range / Resolution

A-B,A-GND,B-GND
-400 to +400VDC / 1 VDC

Line Voltage
  • Range / Resolution

-400 to +400VDC / 1 VDC

Tel: +44 (0) 1249 816 181 • Fax: 01249 816 186
Email: sales@sebakmtuk.com