sebakmt UK - Innovative ideas for location, inspection and fault finding
Sunday, September 17, 2006
Water Leak Detection
HL 500
PAL Automatic Levels
The HYDROLUX HL500 is the perfect device for an ambitious newcomer in leak detection. The most important features for a propper leak detection are implemented into this comprehensive leak detector. There is hardly another device in this market segment offering such comfort and accoutrement.

The equipment can be used either in networks for the supply of drinking water as well as on other pipe systems, provided that the liquid comes out of the pipe under pressure and that the resulting noise carries to the surface of the ground.

  • see and hear leaks with unique DSA-technology
  • 9 fixed frequnecy settings for reduction of ambient noise and better leak detection
  • best sound quality to find small leaks to
  • Unique Histograph-measurment for displaying leaks graphically
  • Modern LCD-Display

Microphones
Also very effective are the piezo-microphones especially designed for the HYDROLUX family. The windprotected microphone PAM W-1 and the new universal microphone are truly professional equipment and first choice for preofessionals and newcomers.

HL 500 Pro

  • Leak detection amplifier    HLE 500
  • Ground-microphone    PAM W-1
  • Tripod for uneaven surfaces for PAM W-1
  • connection lead    VK 65
  • headphone    KR 2
  • carrying strap
  • Robust case for equipment HLK

Additional accessories:

  • Universal mikrophone PAM U
  • head phone (avionic style) KM 2

Technical Data

Input: for piezo microphones
DSP-Technology: integrated / digital audio codec
Protection class: IP 54
Gain: 120 dB = 106-times
Filter frequencies(Hz): 70-106-160-240-360-540-800-1200-1800
Setable filters: 9 filter settings
Range of frequencyanalysis: 40-4000 Hz
Histograms / memory: 9 DSA-values (shift memory) 
LCD display: 130 x 36 mm, backlight
Power supply: 8 St. batteries 1,5 V
8 St. rechargeables 1,2 V (optional)
Operating time: 35 h (batteries), >15h rechargeables
Dimensions: 215 x 95 x 110 mm
Operating temperature: -10° to +50°C
Storage temperature: -10° to +70°C
Weight: with Batteries: 1,2 kg (incl. battery)
Weight: PAM W-1: 3,5 kg (incl. carrying pole)
Weight: PAM U: 500g
Tel: +44 (0) 1249 816 181 • Fax: 01249 816 186
Email: sales@sebakmtuk.com